Warranty Guide
Leading the Way
17
Unacceptable Surfaces:
• Inter-ex and any perimeter bonded products • Carpet
• Any oating oor system • Cork
• Resilient tile installed below grade • Cushion-back vinyl
IVC US will not warrant or accept responsibility of any kind for ooring failures related to the use of
unacceptable substrates and surfaces.
Floor Preparation:
Floor must be clean, smooth, at and dry. Remove all foreign substances such as wax, grease, dirt, construction
markings and contaminants, and any substance or chemical that would interfere with a good bond. Fill all
holes and cracks with a latex fortied Portland cement based patching compound. IVC US only recommends
the use of latex fortied Portland cement based products as a satisfactory patching or leveling compound.
IVC US recommends priming extremely porous oors with IVC FLEX -PRIM Acrylic Latex Primer to prevent
over absorption of adhesives, dust containment, and to insure a better bond of the adhesive to the suboor/
underlayment.
Moisture Testing: It is the responsibility of the ooring contractor and the installer to conrm all concrete
substrates, both old and new, for moisture transmission using the Calcium Chloride Moisture Test according
to ASTM F-1869. Moisture vapor transmission should not exceed the recommended levels of 8 lbs. or less per
1,000 sq. ft. in 24 hours. This test should be performed and documented prior to installation. A second testing
option determinesrelative humidity in concrete oor slabs using In-Situ Probes, which should be less than
90% RH per ASTM F-2170 before, during and after installation. These acceptable moisture readings are only
applicable when using iGrip adhesive for sheet vinyl.
PH LEVELS: PH must be between 5 and 9
Inspection of ooring material prior to installation is required. Any defects should beimmediately reported to
the retail store from which the ooring was purchased before installation. IVC US will not be responsible for
labor costs to repair or replace material with defects that were apparent before or noticed at the end of an
installation. The job site and all ooring material and adhesive must be kept for 24 hours before, during and
after installation between 65˚ F and 85˚ F (18°C and 29°C).
PLEASE NOTE: If removal of existing resilient oor covering is required, follow all recommended Resilient Floor
Covering Institute (RFCI) work practices at www.rfci.com.
IVC US Residential Installation Guide – Sheet Vinyl Flooring
Application
Width x Depth x Spacing
Trowel Specications
Spread Rate Type of Installation
1/16” x 1/32” 1/32” U Trowel
1.6 mm x 0.8 mm x 0.8 mm U
Up to 350 sq. ft./ gal
Up to 8.6 sq. meters / liter
Porous and
Non-Porous Substrate
This document is reviewed on an ongoing basis. Control # MKF_0036_0 11/7/2014