BPHV IT T Commercial Water Goulds Pumps PHV – Packaged Hydrovar Series Variable Speed Water Booster with Vertical Multistage Pump and Fused Disconnect C UL ® US Listed Engineered for life
Goulds Pumps PHV - Packaged Hydrovar Series CONTENTS Selection Chart… …………………………………………………………………………………………… 3 Main Components…………………………………………………………………………………………… 4 Part Numbering……………………………………………………………………………………………… 5 Markets and Applications………………………………………………………………………………… 6-8 Hydrovar Specifications / Listings………………………………………………………………………… 9-11 Multi-Pump Example………………………………………………………………………………………… 12 Operation / Selecting………………………………………………………………………………………… 13 Fused Disconnect… ………………………………………………………………………………………… 1
PHV SERIES SELECTION CHART (PACKAGED HYDROVAR) HYDRAULIC PERFORMANCE RANGE AT 60 Hz SSV FLOW Pump Stage HP 0 GPM Model 5 7.5 10 12.5 15 17.
Goulds Pumps PHV - Packaged Hydrovar Series MAIN COMPONENTS of PHV Series constant pressure variable speed system • One multistage vertical pump, Goulds Pumps SSV series. • Hydrovar® pump mounted variable speed drive • Pressure transducer for constant pressure control, connected to the Hydrovar drive. • NEMA 4X fused disconnect panel with corrosion resistant durable plastic; external on/off switch with lockout/tagout. Panel is bracket mounted directly to pump.
PART NUMBERING / IDENTIFICATION CODES — PHV SERIES PACKAGED HYDROVAR VARIABLE SPEED SSV PRODUCT LINE NUMBERING SYSTEM The various versions of the PHV line are identified by a product code number on the pump label. The number is also the catalog number for the package. The meaning of each digit in the product code is shown below.
Goulds Pumps PHV - Packaged Hydrovar Series MARKETS AND APPLICATIONS Booster Sets MARKETS SERVED MUNICIPAL, COMMERCIAL, INDUSTRIAL APPLICATIONS • Water network supply in condominiums, offices, hotels, shopping centers, factories, water treatment, process control. • Water supply to agricultural water networks (e.g. irrigation). • Variable flow / demand applications requiring constant pressure control. PHV Series SPECIFICATIONS • Flow rate up to 320 GPM. • Maximum HP: 15 HP. • Head up to 692’ TDH.
MARKETS AND APPLICATIONS (continued) WATER SUPPLY AND PRESSURE BOOSTING • Pressure boosting in buildings, hotels, residential complexes • Pressure booster stations, supply of water networks • Booster packages WATER TREATMENT • Ultrafiltration systems • Reverse osmosis systems • Water softeners and de-mineralization • Distillation systems • Filtration LIGHT INDUSTRY • Washing and cleaning plants (washing and degreasing of mechanical parts, car and truck wash tunnels, washing of electronic industry circuits)
Goulds Pumps PHV - Packaged Hydrovar Series MARKETS AND APPLICATIONS (continued) MUNICIPAL, AGRICULTURAL, LIGHT INDUSTRY, WATER TREATMENT, HEATING AND AIR CONDITIONING APPLICATIONS • Handling of water, free of suspended solids, in the municipal, industrial and agricultural markets • Pressure boosting and water supply systems • Fire fighting jockey pumps • Irrigation systems • Wash systems • Water treatment plants: reverse osmosis • Handling of moderately aggressive liquids, demineralized water, water and
MAIN CHARACTERISTICS OF FREQUENCY CONVERTERS USED IN THE PHV BOOSTER SETS The PHV series booster sets use a Hydrovar® variable frequency drive, an automatic device that adjusts the speed of the electric pump in order to maintain constant pressure in the system. Converters with power up to 30 HP can be mounted directly on to the motor. Models with over 30 HP power, are designed for wall mounting only. The pressure is measured by a pressure transmitter which uses a standard 4..20 mA current signal.
Goulds Pumps PHV - Packaged Hydrovar Series CHARACTERISTICS OF THE ELECTRIC PUMPS USED IN PHV SERIES BOOSTER PACKAGE 1, 2, 3 AND 4 SSV VERTICAL MULTI-STAGE PUMPS • Reduced axial thrusts enable the use of standard motors that are easily found on the market. • Standard Baldor, NEMA motors • Easy maintenance. No special tools required for assembly or disassembly. • ANSI/NSF 61 certified by CSA for potable drinking water. • Multistage centrifugal vertical electric pumps.
HYDROVAR VERSIONS INTRODUCTION The HYDROVAR Concept consists mechanically of two main parts, the Power Unit and the Control Card. In its basic configuration (consists only of the Power Unit) the HYDROVAR can be used as a “Basic Inverter” without the need of the Control Card. In that form the HYDROVAR can be used as a sequence pump in a multi pump system, with at least one master inverter.
Goulds Pumps PHV - Packaged Hydrovar Series APPLICATION EXAMPLE – MULTI-PUMP “CASCADE” MASTER INVERTER MASTER INVERTER MASTER INVERTER MASTER INVERTER RS 485 CONNECTION With the “master” version of the Hyrdrovar, it is possible to connect up to 8 Hydrovar controller pumps together in parallel. Complete lead/lag and auto alternation.
OPERATION DESCRIPTION SETS WITH VARIABLE-SPEED MOTORS AND PRESSURE TRANSDUCER CONTROL The starting and stopping of the pumps are determined based on the pressure values set on the controller. Each frequency converter is connected to a pressure transducer. The controllers exchange information with each other and provide for cyclic changeover. The figure shows the operating mode of a two-pump booster set (Typical Field Set). • On demand, water is drawn from the tank.
Goulds Pumps PHV - Packaged Hydrovar Series SELECTING A SET The first thing to do when selecting a package is to determine the quantity of water required and the pressure it must supply. CALCULATING THE FLOW RATE • The quantity of water called water requirement depends on the type of users, e.g. homes, offices, schools, as well as their number. The theoretic requirement is the total amount of water required by all the users.
FUSED DISCONNECT BOX: DISCONNECT CUSTOMER SUPPLIED FUSE BLOCK HYDROVAR SINGLE PHASE CUSTOMER SUPPLIED VOLTAGE L1 L2 1 2 3 4 5 6 12 AWG U1 12 AWG GND DISCONNECT U2 V1 V2 W1 W2 PE GND MTR 16 AWG MOTOR GND CUSTOMER SUPPLIED FUSE BLOCK HYDROVAR THREE PHASE CUSTOMER SUPPLIED VOLTAGE L1 L2 L3 1 2 3 4 5 6 12 AWG U1 12 AWG 12 AWG GND ITT Disconnect Part Number U2 V1 V2 W1 W2 PE GND MTR 16 AWG MOTOR GND Input Disconnect Voltage HP / AMP Rating Wire Range
Goulds Pumps PHV - Packaged Hydrovar Series SPECIFICATIONS Hydrovar VFD HP 2 3 3 5 7½ 10 15 Model * HVM1202 HVM1203 HVM3403 HVM3405 HVM3407 HVM3410 HVM3415 Power Supply (V) 1x230 1x230 3x460 3x460 3x460 3x460 3x460 Motor NEMA Class 4 4 4 4 4 4 4 Install. TEFC Motor TEFC Motor TEFC Motor TEFC Motor TEFC Motor TEFC Motor TEFC Motor Power Supply (V) 3x230 3x230 3x460 3x460 3x460 3x460 3x460 HP 2 3 3 5 7½ 10 15 * The new Hydrovar is available single-phase up to 3 HP and 3 HP through 15 HP, 460 volt.
MOTOR DATA 3500 RPM, 60 Hz HP Phase Enclosure Nameplate Voltage NEMA Frame Goulds FLA SFA PN LRA S.F. Efficiency Insulation ¹ Class TEFC 230/460 56C V06742 3.7-3.6/1.8 3.99-3.8/1.9 11 1.25 75.5 B Prem. Eff. TEFC 230/460 56C V06742PE 2.8/1.4 3.12/1.56 12.1 1.25 84.5 B TEFC 230/460 56C V07742 4.9-4.6/2.3 5.3-5.1/2.54 18.4 1.15 80 B Prem. Eff. TEFC 230/460 56C V07742PE 4.0/2.0 4.5/2.25 20.1 1.15 85.5 B 2* 3 TEFC 208-230/460 56C V08742 6.2-5.8/2.
Goulds Pumps PHV - Packaged Hydrovar Series PERFORMANCE WITH VARYING SPEED FOR CENTRIFUGAL PUMPS Fitting the electric pump with a variable speed drive makes it possible to vary the pump rotation speed, normally according to the system pressure parameter. Variations in electric pump speed result in modified performances according to the equivalence relations, called affinity laws.
VARIABLE SPEED PERFORMANCE CURVES 1SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 298 feet Maximum Flow Flow at Duty Point 22 US GPM Fluid: Water, pure [FT] Head 6 300 MODEL: 1SVB 6 Stage NPSHR Duty Chart: 3500 RPM Application Range 280 260 240 220 200 180 160 140 120 60 Hz 100 80 50 Hz 60 40 Hz 40 30 Hz 20 0 [FT] NPSH - values 7 6 60 Hz 5 4 3 2 1 0 [HP] Shaft power P2 1.6 1.4 ) 1.2 6 (P2 1 0.8 0.6 0.4 0.
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 1SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 442 feet Maximum Flow Flow at Duty Point 22 US GPM Fluid: Water, pure [FT] Head 9 440 MODEL: 1SVB 9 Stage NPSHR Duty Chart: 3500 RPM Application Range 400 360 320 44.5% 280 240 44.5% 200 60 Hz 160 44.5% 120 80 50 Hz 40 Hz 44.
VARIABLE SPEED PERFORMANCE CURVES 1SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 733 feet Maximum Flow Flow at Duty Point 22 US GPM Fluid: Water, pure [FT] Head 760 15 720 680 640 600 560 520 480 440 400 360 320 280 240 200 160 120 80 40 0 [FT] NPSH - values 7 6 NPSHR Duty Chart: 3500 RPM Application Range 44.5% 44.5% 60 Hz 44.5% 50 Hz 40 Hz 44.5% 30 Hz 60 Hz 5 4 3 2 1 0 Shaft power P2 [HP] 4 3.5 2) 3 15 (P 2.5 2 1.5 1 0.
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 2SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 217 feet Maximum Flow Flow at Duty Point 40 US GPM Fluid: Water, pure MODEL: 2SVB 5 Stage NPSHR Duty Chart: 3500 RPM [FT] Head 5 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 [FT] NPSH - values Application Range 57.1% 57.1% 60 Hz 50 Hz 57.1% 40 Hz 57.
VARIABLE SPEED PERFORMANCE CURVES 2SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 353 feet Maximum Flow Flow at Duty Point 40 US GPM Fluid: Water, pure [FT] Head 360 8 MODEL: 2SVB 8 Stage NPSHR Duty Chart: 3500 RPM Application Range 340 320 300 280 260 240 220 57.1% 200 180 160 57.1% 140 120 100 60 Hz 50 Hz 57.1% 80 60 40 40 Hz 57.1% 30 Hz 20 0 [FT] NPSH - values 60 Hz 10 50 Hz 8 40 Hz 6 4 30 Hz 2 0 [HP] 2.
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 2SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 586 feet Maximum Flow Flow at Duty Point 40 US GPM [FT] 600 Fluid: Water, pure Head MODEL: 2SVB 13 Stage NPSHR Duty Chart: 3500 RPM Application Range 13 560 520 480 440 400 360 57.1% 320 280 240 57.1% 60 Hz 200 160 50 Hz 57.1% 120 80 40 Hz 57.
VARIABLE SPEED PERFORMANCE CURVES 3SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 441 feet Maximum Flow Flow at Duty Point 78 US GPM Fluid: Water, pure [FT] Head 7 440 MODEL: 3SVB 7 Stage NPSHR Duty Chart: 3500 RPM Application Range 400 360 320 280 240 60 Hz 200 160 50 Hz 120 40 Hz 80 30 Hz 40 0 [FT] NPSH - values 60 Hz 12 50 Hz 10 8 40 Hz 6 30 Hz 4 2 [HP] 0 7 Shaft power P2 60 Hz 6 5 50 Hz 2) 4 7 (P 3 2 40 Hz 1 0 30 Hz 0
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 3SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 565 feet Maximum Flow Flow at Duty Point 78 US GPM Fluid: Water, pure [FT] Head 9 560 MODEL: 3SVB 9 Stage NPSHR Duty Chart: 3500 RPM Application Range 520 480 440 400 360 320 280 60 Hz 240 200 50 Hz 160 120 40 Hz 80 30 Hz 40 0 [FT] NPSH - values 60 Hz 12 50 Hz 10 8 40 Hz 6 30 Hz 4 2 [HP] 0 Shaft power P2 9
VARIABLE SPEED PERFORMANCE CURVES 3SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 817 feet Maximum Flow Flow at Duty Point 78 US GPM Fluid: Water, pure Head [FT] 13 800 MODEL: 3SVB 13 Stage NPSHR Duty Chart: 3500 RPM Application Range 750 700 650 600 550 500 450 400 60 Hz 350 300 50 Hz 250 200 40 Hz 150 100 30 Hz 50 0 [FT] NPSH - values 60 Hz 12 50 Hz 10 8 40 Hz 6 30 Hz 4 2 0 [HP] Shaft power P2 60 Hz 12 10 8 50 Hz P2) 13 (
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 4SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Maximum Flow Flow at Duty Point 112 US GPM Fluid: Water, pure MODEL: 4SVB 2 Stage Hydraulic Data Maximum TDH TDH at Duty Point 148 feet NPSHR Duty Chart: 3500 RPM [FT] Head 2 150 Application Range 140 130 120 110 100 60 Hz 90 80 70 50 Hz 60 50 40 Hz 40 30 30 Hz 20 10 0 [FT] NPSH - values 14 12 10 8 6 4 2 0 -2 [HP] 4.5 Shaft power P2 4 3.5 3 2.5 2 1.5 1 0.
VARIABLE SPEED PERFORMANCE CURVES 4SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 299 feet Maximum Flow Flow at Duty Point 112 US GPM Fluid: Water, pure [FT] Head 4 300 MODEL: 4SVB 4 Stage NPSHR Duty Chart: 3500 RPM Application Range 280 260 240 220 200 60 Hz 180 160 140 50 Hz 120 100 80 40 Hz 60 30 Hz 40 20 0 [FT] NPSH - values 14 12 10 8 6 4 2 0 -2 [HP] Shaft power P2 8 7 6 5 4 2) 3 4 (P 2 1 0 0 10 20 60 Hz 50 Hz 40 Hz 30 Hz 60 Hz 50 H
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 4SV VARIABLE SPEED CURVE SSVB 304SS Multi-Stage Pumps Maximum Flow Flow at Duty Point 111 US GPM Fluid: Water, pure [FT] Head 7 520 MODEL: 4SVB 7 Stage Hydraulic Data Maximum TDH TDH at Duty Point 526 feet NPSHR Duty Chart: 3500 RPM Application Range 480 440 400 360 60 Hz 320 280 240 50 Hz 200 160 40 Hz 120 80 30 Hz 40 0 [FT] NPSH - values 14 12 10 8 6 4 2 0 -2 [HP] Shaft power P2 14 12 60 Hz 50 Hz 40 Hz 30 Hz
VARIABLE SPEED PERFORMANCE CURVES 33SV VARIABLE SPEED CURVE SVB CI/316SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 83 feet Maximum Flow Flow at Duty Point 225 US GPM Fluid: Water, pure [FT] Head 85 STAGE 1/1 80 MODEL: 33SVB 1/1 Stage NPSHR Duty Chart: 3500 RPM Application Range 75 70 65 60 55 50 45 40 60 Hz 35 30 25 50 Hz 20 40 Hz 15 10 30 Hz 5 0 [FT] NPSH - values 60 Hz 30 50 Hz 25 20 40 Hz 15 30 Hz 10 5 STAGE 1/1 0 [HP] Shaft power P2 3.5 3 2.
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 33SV VARIABLE SPEED CURVE SVB CI/316SS Maximum Flow Flow at Duty Point 224 US GPM Fluid: Water, pure [FT] Head 115 STAGE 1 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 [FT] NPSH - values Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 110 feet NPSHR Duty Chart: 3500 RPM Application Range 76.7% 60 Hz 76.7% 50 Hz 76.7% 40 Hz 76.
VARIABLE SPEED PERFORMANCE CURVES 33SV VARIABLE SPEED CURVE SVB CI/316SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 191 feet Maximum Flow Flow at Duty Point 225 US GPM Fluid: Water, pure [FT] Head 200 STAGE 2/1 190 180 170 160 150 140 130 120 110 100 NPSHR Duty Chart: 3500 RPM Application Range 76.7% 60 Hz 76.7% 90 80 70 60 50 40 30 20 10 0 [FT] NPSH - values 50 Hz 76.7% 40 Hz 76.
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 33SV VARIABLE SPEED CURVE SVB CI/316SS Maximum Flow Flow at Duty Point 225 US GPM Fluid: Water, pure Head 320 STAGE 3/1 300 Multi-Stage Pumps MODEL: 33SVB 3/1 Stage Hydraulic Data Maximum TDH TDH at Duty Point 310 feet NPSHR Duty Chart: 3500 RPM [FT] Application Range 280 260 240 76.7% 220 200 180 60 Hz 76.7% 160 140 120 50 Hz 76.7% 100 80 40 Hz 60 76.
VARIABLE SPEED PERFORMANCE CURVES 46SV VARIABLE SPEED CURVE SVB CI/316SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 100 feet Maximum Flow Flow at Duty Point 319 US GPM Fluid: Water, pure [FT] Head 105 STAGE 100 1/1 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 [FT] NPSH - values 16 14 12 10 8 6 STAGE 1/1 4 2 0 [HP] Shaft power P2 4.5 (P2) 4 STAGE 1/1 3.5 3 2.5 2 1.5 1 0.5 0 60 0 20 40 MODEL: 46SVB 1/1 Stage NPSHR Duty Chart: 3500 RPM Application Range 77.6% 77.
Goulds Pumps PHV - Packaged Hydrovar Series VARIABLE SPEED PERFORMANCE CURVES 46SV VARIABLE SPEED CURVE SVB CI/316SS Multi-Stage Pumps Hydraulic Data Maximum TDH TDH at Duty Point 123 feet Maximum Flow Flow at Duty Point 319 US GPM Fluid: Water, pure [FT] 130 Head STAGE 1 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 [FT] NPSH - values 16 14 12 10 8 6 STAGE 1/1 4 2 0 [HP] Shaft power P2 6 STAGE 1 (P2) MODEL: 46SVB 1 Stage NPSHR Duty Chart: 3500 RPM Application
TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING 1SV 3500 RPM Number of Stages 22 20 18 16 15 13 11 9 8 7 6 5 4 3 2 Maximum HP Draw 6.7 6.1 5.4 4.8 4.6 4 3.4 2.7 2.4 2 1.8 1.5 1.1 0.9 0.6 Motor HP for use With 1.15 SF Motor 7.5 7.5 5 5 5 5 3 3 3 2 2 1.5 1 3/4 1/2 Motor HP for use With Hydrovar (1.0 SF) 7.5 7.5 7.5 5 5 5 5 3 3 2 2 1.5 1.5 1 3/4 Shutoff TDH (Feet) 1100 1005 905 795 742 642 550 445 398 350 300 250 200 142 100 Shutoff TDH (Bar) 32.8 30.0 27.0 23.7 22.2 19.2 16.4 13.3 11.9 10.4 9.0 7.5 6.
Goulds Pumps PHV - Packaged Hydrovar Series TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING 4SV 3500 RPM Number of Stages 12 10 9 8 7 6 5 4 3 2 Maximum HP Draw 26.4 21.6 19.2 16.9 14.9 12.9 10.7 8.6 6.3 4.3 Motor HP for use With 1.15 SF Motor 25 20 20 15 15 15 10 7.5 7.5 5 Motor HP for use With Hydrovar (1.0 SF) NA 25 20 20 15 15 15 10 7.5 5 Shutoff TDH (Feet) 930 780 700 620 540 460 390 305 228 150 Shutoff TDH (Bar) 27.8 23.3 20.9 18.5 16.1 13.7 11.6 9.1 6.8 4.
TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING 46SV 3500 RPM # of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing / Sleeve Stages requiring Pump Flange # reduced HP with 1.15 SF with Hydrovar TDH TDH Pressure rating Thrust Balancing Rating Diameter Draw Motor (1.0 SF) (Feet) (Bar) (Standard Assy.) Piston 10/2 77.8 1210 36.1 9 73.2 1137 33.9 75 9/1 71.5 1111 33.2 9/2 69.7 1085 32.4 75 8 65 1010 30.2 8/1 63.3 984 29.4 60 8/2 61.6 959 28.
Goulds Pumps PHV - Packaged Hydrovar Series TECHNICAL DATA Maximum Inlet Pressure The following table shows the maximum permissible inlet pressure. However, the actual inlet pressure + pressure against a closed valve must always be lower than the maximum permissible operating pressure.
PHV — PACKAGED HYDROVAR SERIES — 1SVB DI L2 Weights (lb.) Frame (max.) Stage (3-Phase) HP L1 MI Liquid Disconnect TEFC TEFC L6 L7 L8 TEFC TEFC Hydrovar (ref.) End Box 6 56C 9 15 182-4TC 2 3 5 16.63 12.06 19.56 13.44 6.70 25.44 15.43 20.90 9.87 5.73 7.19 23.83 29.71 11.15 6.87 8.
Goulds Pumps PHV - Packaged Hydrovar Series PHV — PACKAGED HYDROVAR SERIES — 2SVB DI L2 Weights (lb.) Frame (max.) Stage (3-Phase) HP L1 MI Liquid Disconnect TEFC TEFC L6 L7 L8 TEFC TEFC Hydrovar (ref.) End Box 5 2 56C 8 3 13 182-4TC 5 16 15.63 12.06 18.56 13.88 6.70 23.50 15.44 26.44 19.90 5.75 9.87 7.19 22.83 5.50 27.77 11.15 6.88 8.50 30.
PHV — PACKAGED HYDROVAR SERIES — 3SVB DI L2 Weights (lb.) Frame (max.) Stage (3-Phase) HP L1 MI Liquid Disconnect TEFC TEFC L6 L7 L8 TEFC TEFC Hydrovar (ref.) End Box 2 56C 2 15.75 12.06 20.02 9.87 5.75 7.19 33 51 4 3 18.75 23.02 37 85 182-4TC 15.44 6.70 27.52 6.88 8.50 7 7½ 23.25 45 124 10 5 11.15 9 215TC 10 28.88 15.50 33.15 8.06 10.25 47 151 13 254TC 15 33.38 16.56 37.65 9.25 10.
Goulds Pumps PHV - Packaged Hydrovar Series PHV — PACKAGED HYDROVAR SERIES — 4SVB DI L2 Weights (lb.) Frame (max.) Stage (3-Phase) HP L1 MI Liquid Disconnect TEFC TEFC L6 L7 L8 TEFC TEFC Hydrovar (ref.) End Box 2 5 15.75 20.02 33 85 182-4TC 15.44 6.70 23.02 11.15 6.88 8.50 4 7½ 18.75 39 124 10 5 7 254TC 15 24.44 16.56 28.71 9.25 10.
PHV — PACKAGED HYDROVAR SERIES — 33SVB DI L2 Weights (lb.) Frame (max.) Stage (3-Phase) HP L1 MI Liquid Disconnect TEFC TEFC L6 L7 L8 TEFC TEFC Hydrovar (ref.) End Box 1/1 182-4TC 5 20.62 15.44 13.95 6.88 8.50 132 85 10 1 6.70 16.91 12.27 5 2/1 215TC 10 23.58 15.50 8.06 10.25 143 151 18 3/1 254TC 15 26.54 16.56 19.87 9.25 10.
Goulds Pumps PHV - Packaged Hydrovar Series PHV — PACKAGED HYDROVAR SERIES — 46SVB DI L2 Weights (lb.) Frame (max.) Stage (3-Phase) HP L1 MI Liquid Disconnect TEFC TEFC L6 L7 L8 TEFC TEFC Hydrovar (ref.) End Box 1/1 182-4TC 7½ 15.44 6.88 8.50 124 22.19 15.50 6.70 15.52 12.27 147 10 1 215TC 10 8.06 10.25 151 5 2/1 254TC 15 25.19 16.56 18.52 9.25 10.
NPSH The maximum possible suction head for installation depends on the value of the atmospheric pressure (i.e. the elevation above sea level at which the pump is installed) and the temperature of the liquid. The minimum operating values that can be reached at the pump suction end are limited by the onset of cavitation.
Goulds Pumps PHV - Packaged Hydrovar Series TECHNICAL DATA – WATER PROPERTY CHART Temp ºF Temp ºC 32 0.0 35 1.7 40 4.4 50 10.0 60 15.6 70 21.1 80 26.7 90 32.2 100 37.8 120 48.9 140 60.0 160 71.1 180 82.2 200 93.3 212 100.0 220 104.4 240 115.6 260 126.7 280 137.8 300 148.9 320 160.0 340 171.1 360 182.2 380 193.3 400 204.4 420 215.6 440 226.7 460 237.8 480 248.9 500 260.0 520 271.1 540 282.2 560 293.3 580 304.4 600 315.6 620 326.7 640 337.8 660 348.9 680 360.0 700 371.
VOLUMETRIC CAPACITY Litres per minute l/min Cubic metres per hour m3/h Cubic feet per hour ft3/h Cubic feet per minute ft3/min Imp. gal. per minute Imp. gal/min US gal. per minute Us gal.
Goulds Pumps PHV - Packaged Hydrovar Series NOTES 50
NOTES 51
ITT 2881 East Bayard Street, Seneca Falls, NY 13148 Phone: (315) 568-7123 • Fax: (315) 568-7973 www.goulds.com Goulds Pumps and G&L are registered trademarks of ITT Corporation. ITT, the Engineered Blocks Symbol and Engineered for Life are registered trademarks of ITT Manufacturing Enterprises, Inc. Copyright © 2009 ITT Corporation BPHV September, 2009 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Printed in U.S.A.