Datasheet
24
www.ittcannon.com
Dimensions shown in mm
Specifications and dimensions subject to change
N
o. Contact arrangement Service Insulator position Po si tion Special Insulator weight
o
f Contact size rating polarization (g)
C
ontacts VG CA NVWXY Z including contacts
pin socket
–––––– 2 260
5
4 32A10 –––––– 3 110
– 16 A––80 110 250 280 4 80 89 132
–––––– 8 250
–
––––– 9 280
–––––– 12 100
–––––– 2 260
47 – 32A47 –––––– 3 110
16 A––––––480 73 120
–––––– 8 250
–
––––– 9 280
–––––– 12 100
55 32A55
16 A––80 110 250 280 ––90 134
6
1 32A69 32A69 Instr. 0 ––110 250 –– – 49 84
2
0 15 16
41 10 20
Not for through-bulkhead receptacle C1 / C2.
6 36-3 36-3
3 500/0 0D 0 – 70 145 215 290 ––165 200
3 25/12 12
All alternating insert position as above are permitted for VG95234 type.
4 36-5 36-5 A 0 ––120 240 –– – 152 181
500/0 0
6 36-6 36-6
44 4 A 0 – 35 110 250 325 ––155 173
20 0
Cannon VG/CA-Bayonet
View on Mating
face of Pin Insulator
Attention: for all alternate positions of these contact arrangements a tendency to overmate can be stated.
It is within the customer’s responsibility to use these insert positions.