Datasheet

22
www.ittcannon.com
Dimensions shown in mm (inch)
Specifications and dimensions subject to change
Cannon Trident Connectors
Multiway Rack & Panel Connectors
The Multiway Range has six contact cavity
arrangements available and offers an
extremely reliable, robust and versatile
connector system, in which any of the
Trident signal or coaxial contacts can be
used. All Multi Rack & Panel connectors
are RoHS Compliant.
Applications:
Inflight entertainment systems.
Railway applications.
Test measurement equipment.
Product Features
Fully tested to MIL-STD-202 and now IEC 512.
Wide range of accessories, jacking and mounting hardware.
Polarizing between connectors available, by contact position, use of
shrouds or additional guide pin and socket sets.
Recognized under the component program of CSA.
Complete range of contact options available, see page 64.
Performance Specifications
Materials and Finishes
Insulator Glass-Filled Phenolic
Intermating Hardware Brass and Stainless Steel
Jackscrew Knobs Thermoplastic
Cable Clamps Stainless Steel
Pin Protection Shrouds, 14-34-way Anodized Aluminum
Pin Protection Shrouds, 50 & 75-way Stainless Steel
Formed Hoods Anodized Aluminum
Plastic Hoods Unfilled Thermoplastic - PPO
Die Cast Hoods Grey Painted Zinc Alloy
Test Data
Test Description IEC Test Military Standard Test Method
Test Voltage 512-2 Test 4a MIL-STD-202 301
Insulation Resistance 512-2 Test 3a MIL-STD-202 302
Vibration 512-4 Test 6d MIL-STD-202 204, Condition A
Shock 512-4 Test 6c MIL-STD-202 213
Humidity 512-6 Test 11c MIL-STD-202 103, Condition C
Corrosion (Salt Spray) 512-6 Test 11f MIL-STD-202 101, Condition B
Dry Heat 512-6 Test 11i MIL-STD-202 108A, Condition D
- Temperature Range -55°C to +125°C (-67°F to +257°F) Plastic Hood
assemblies limited to 105°C to (221°F)
Test Voltage 200 V ac rms for 60 seconds
Insulation Resistance 5000MW min. at 500 V dc
Durability¹ Up to 500 Mating Cycles
Flammability UL 94 V-0 (Insulators), UL 94 V-1 (Plastic Hoods)
Rated Current Dependent on choice of contact and application
(usually limited by cable bundle factor)
1
Depends on plating and type of contacts used