Completing Gel-cap Connections Using the
Itron Splice Kit
Important! All unused wires on 500WERT modules must be terminated. Wire
terminations must be properly sealed with a non-conductive gel material to prevent
water intrusion and possible environmental or electrical issues.
Required Materials
E-9R 3M® gel connector crimping tool (or other 3M approved crimping tool)
Itron splice kit (part number OEM-0034-002)
1. Push two wires as far as possible into the connector.
Caution: Do not strip insulation from the ends of the wires before inserting them
into the connector.
2. Carefullyplace the connector and wires into the jaws of the crimping tool. Make sure the
wires remain fully inserted in the gel-cap connector.
3. Crimp the connector by squeezing the handles until the connector cap is fully seated.
Continue to apply pressure for three seconds.