4. To wire the 500W ERT remote module to the RTR 2-wire register, connect the remote
500W ERT module wires to the 2-wire register using gel-cap connectors. After the wires
are connected, carefully tuck the connectors into the remote 500W ERT module housing.
5. Place the remote 500W ERT module on the register, ensuring that the edge of the remote
500W ERT module housing is seated properly around the perimeter of the register as
shown.
Note: A gasket is not required.
6. Install four Torx-head mounting screws (SCR-0010-005) and hand-tighten the screws.
500W ERT Module Remote Installation Guide 4 Installing the Remote 500W ERT Module
30 June 2021 815-0005-00 REV 008 Itron, Inc. Page 37 of 45