Installation Guide

Table Of Contents
1. The remote 500W ERT module has three wires that connect to the register:
1 brown insulated wire
2 yellow insulated wire
3 gray insulated wire
Note: For an RTR register, tuck the unused yellow wire into the housing.
2. Connect the remote 500W ERT module wires to the register using gel-cap connectors
following the remote 500W ERT module to the Badger ADE register wire connections (see
Encoder-type Register Connections on page 18).
3. After the wires are connected, carefully tuck the connectors into the remote 500W ERT
module housing.
500W ERT Module Remote Installation Guide 4 Installing the Remote 500W ERT Module
30 June 2021 815-0005-00 REV 008 Itron, Inc. Page 36 of 45