1. Push the hollow pin (1) completely out of its location and separate the remote 500W ERT
module mounting bracket (2) from the meter register collar (3).
2. Strip 1/2-inch of insulation from the end of the brown, gray, and yellow wires.
3. Place the remote 500W ERT module on the mounting bracket and route the yellow, gray,
and brown wires through the opening.
Note: A gasket is not required.
4. Install four Torx-head mounting screws (Itron part number SCR-0010-005).
5. Hand-tighten each screw.
6. Connect the remote 500W ERT module wires to the register screw terminals following the
remote 500W ERT module to the Elster/AMCO meter register wire connections. After the
wires are connected, carefully tuck the connectors into the remote 500W ERT module
housing. Tighten all screws securely.
500W ERT Module Remote Installation Guide 4 Installing the Remote 500W ERT Module
30 June 2021 815-0005-00 REV 008 Itron, Inc. Page 34 of 45