Note: A tamper seal is fully seated when the top of the tamper seal is approximately
1/16 inch below the top of the screw recess.
7. Secure any excess cable using the provided cable ties.
Direct-mounting to the Meter Register
Direct-mounting remote 500W ERT modules to a meter register requires a register designed
for that purpose. This section describes remote 500W ERT module installation for the
following direct mount registers:
Badger ADE and RTR
Elster/AMCO (ABB) Scancoder, InVISION, and Digital
Warning! Do not use the direct mounting method in a pit environment. Use a 500W
ERT module for pit environments. OpenWay Riva remote modules direct mounted
in a pit environment are not covered by the Itron warranty.
Direct-mounting on the ABB Scancoder, InVision, or Digital Direct-Mount
Note: Verify that you have an Elster/AMCO meter with a register designed for direct-
mount remote 500W ERT module . Always install the remote 500W ERT module right side
up with the arrow on the housing pointed upward. The register may or may not be mounted
on the meter when performing the following steps.
500W ERT Module Remote Installation Guide 4 Installing the Remote 500W ERT Module
30 June 2021 815-0005-00 REV 008 Itron, Inc. Page 33 of 45