Installation Guide

Table Of Contents
Completing the SET Valve Wire Connections
Connect the remote 500W ERT module wires to the SET valve wires following the
connections shown in the SET Valve/remote 500W ERT module wire connections table.
SET valve to 500W ERT module wiring
Remote module wire color Blue Orange Purple/white
SET shutoff valve wire color Green Red Black
Remote Mount Installation
Connect the remote 500W ERT module to the register as described in Initializing and
Connecting on page 17.
Using a back plate, create a template by drilling through a back plate lug slot to mark the
position of the screw. Use the drilled back plate as your mounting template.
The arrow on the remote 500W ERT module must point up when installation is complete.
Installing on a Flat Surface
1. Select an installation location.
2. Using a back plate template, drill three pilot holes into the wall or other surface. The two
bottom holes should be level.
3. Screw a mounting screw for the lug slot into the surface, leaving approximately 1/8-inch of
the screw protruding. The lug slot should slide over the screw with a tight fit.
500W ERT Module Remote Installation Guide 4 Installing the Remote 500W ERT Module
30 June 2021 815-0005-00 REV 008 Itron, Inc. Page 31 of 45