Installation Guide

Table Of Contents
2. Loosen the band clamp screw until the end of the band releases.
3. Push the end of the clamp's band through the holes in the pipe bracket.
4. Place the band clamp around the pipe. The band will loosely wrap around the pipe.
5. Push the end of the band through the band clamp screw assembly. Turn the band clamp's
screw assembly to fit into the pipe bracket opening. Tighten the clamp screw until the band
clamp is secure on the pipe.
Adapter Plate Mounting Positions
The installation procedure in the previous section shows how to mount the adapter plate on a
vertical pipe.
The following pictures show the adapter plate on 45-degree angle and horizontal pipes.
Regardless of the angle of the pipe, the adapter plate mounting lug (1) must always be at the
top.
If the pipe is at a 45-degree angle up to the right, install the adapter plate with the mounting
screws (2) as shown.
500W ERT Module Remote Installation Guide 4 Installing the Remote 500W ERT Module
30 June 2021 815-0005-00 REV 008 Itron, Inc. Page 28 of 45