Pulser-type Register Connections
Connect the remote 500W ERT module cable to the register according to the following table.
Remote module wire color
Brown Gray Yellow
Register manufacturer Register screw color designator
Badger RTR (3-wire) Red Black Green
Badger RTR (2-wire) Red Black No connection*
Badger M5000 Mag Meter Red terminal: Out 1+ Black terminal: Out 1- White terminal: Out 1+
■ Cadillac Meter CMAG/EMAG
■ Magnetic Flow
DO1/DO2 COM COM
Elster Digital Black Green Red
Elster V100T Red &Black Blue Yellow
■ Itron (Actaris)
■ Flostar (2-wire)
■ Cyble Sensor
Either wire Remaining wire must be connected to both
ERT module wires
Krohne IFC Term B Term H Term B
RG3 Tomahawk Green Black Green
Sensus PMM Red Black Bare
Note: *Itron recommends terminating unconnected wires with a gel-cap connector to
protect the bare wire end.
Connecting Using an Extension Cable
Order the 25-foot inline connector extension cable assembly (CFG-0151-404) to extend the
cable of the 500W ERT module .
Verifying Operation
Use one of the following programming devices to verify that the remote 500W ERT module is
correctly recording consumption data.
■
FC300SR handheld computer
■
Itron Mobile Radio connected to a user-supplied computer or Bluetooth device
Each handheld radio requires special setup and configuration parameters to successfully read
and program remote modules. Refer to the respective meter reading application for specific
instructions. When comparing the actual register value to that reported by the remote 500W
500W ERT Module Remote Installation Guide 3 Initializing and Connecting