The remote 500W ERT module is awakened from quiet mode and enters run mode in
one of two ways:
Counting two pulses. The pulses are counted internal to the 500W ERT module
while it is in quiet mode.
Receiving a two-way command, such as a Read ERT using FDM.
If a remote 500W ERT module installed in quiet mode is not bubbling up SCM+ messages, it
may be due to zero consumption on the remote 500W ERT module , such as a vacant or
vacation home. Initiate a two-way command (for example, perform a Read ERT with FDM)
before removing the unit.
Firmware Functionality
OpenWay Riva
This section lists the OpenWay Riva 500W ERT module firmware information and lists
functionality by version.
Note: Each new version contains the features associated with the previous GSR.
Firmware part
number
Global
software
release
version
(GSR)
FDM Check
Endpoint
firmware version
Over-the-air
firmware part
number
Firmware functionality
FMW-1601-004 4.1 1.3.7
Network topology
IPv6 addressable
60 minute interval data
Mobile Mode
Firmware download
FMW-1602-006 4.5 2.1.10.0 DFW-1602-006
GSR 4.1 functionality
5, 10, 15, 30-minute interval data
Extended meter alarms
Low battery alarm
Local auditing
Restricted water flow state
FMW-1602-012 4.5 2.2.6.0 DFW-1602-012
4.1 GSR compatibility
4.5 2.1.10.0 compatibility
Bug fix to OpenWay Riva Leak Sensor
compatibility
500W ERT Module Remote Installation Guide 2 About the 500WERTModule