This section describes the pit module connections to the water meter register using the inline connector
assembly. Follow the manufacturer's recommended procedure for installing the water meter register on the
meter.
To connect the inline connector
Note If an inline connector is not used and the pit module is already connected to the water meter
register, skip this step.
1. Remove the protective cover from the connector by twisting the two halves in opposite directions. Pull the
halves apart.
Caution Verify the connector halves are clean and dry before assembly.
If any of the following conditions occur, do not install the modules:
Any of the three pins are damaged or missing.
The O-ring is missing.
The cable is cut or nicked.
2. Connect the register cable to the pit module connector:
• Holding the connectors by the black shells, rotate one end to align the keyed slots.
• Push until snug.
• Slide the black coupling nut over the O-ring. Make sure the O-ring stays seated. (If the O-ring does
not stay seated, disconnect and repeat this step.)
• Twist the register cable's black coupling nut to align the two tabs.
3. Install the security seal as shown. Push it until it snaps into place.
Note For future meter or pit module servicing, break the security seal by pulling the seal apart. The
original protective connector covers can be reused if kept clean and dry. Install a new security seal after
servicing either device. To order replacement security seals, see the Water Products Ordering Guide
(PUB-0063-001).
Caution Shield connectors with protective environmental covers (see Pit Module Mounting Accessories
on page 9). Do not leave an exposed connector in the field.
Environmental caps employ multiple seals to increase cap life. Environmental cap design allows utilities
to install the pit module and install a Riva Leak Sensor at a future date.
A PPENDIX B
Using an Inline Connector