Installing the OpenWay Riva Water Pit Module
TDC
-1666-000 OpenWay Riva Water Pit Module Installation Guide 22
Proprietary and Confidential
3. Wrap the entire piece of electrical tape around the pit module cable near the inline connector.
4. Beginning over the installed electrical tape, twist the Itron cable armor onto the pit module cable using a
right-handed twist.
Important You must twist—not wrap—the cable armor onto the pit module cable. Wrapping the cable
armor can cause the stainless steel jacket to warp.
Warning You must begin twisting the cable armor over portion of the cable protected by the electrical
tape. If you do not begin to twist the cable armor over the protected portion of the pit module cable, a cut
cable could cause an pit module/register communication failure.
5. Continue to twist the cable armor onto the pit module cable until the cable armor covers the entire cable.
Warning You must continue to twist the cable armor onto the cable protected by the electrical tape. If
you do not twist the cable armor over the protected portion of the cable, you could initiate a cut cable and
cause and pit module/register communication failure.
6. Remove any leftover materials from the customer premises. Discard or recycle leftover materials.