Installing the OpenWay Riva Water Pit Module
TDC
-1666-000 OpenWay Riva Water Pit Module Installation Guide 20
Proprietary and Confidential
1. Remove the environmental cap from the pit module's blue connector (B).
B. Blue connector: telemetry device connection
A. Black connector: register connection
2. Remove the environmental cap from the remote disconnect valve connector. Verify the connectors (the pit
module's telemetry connector and the disconnect valve connector) are clean and dry.
3. Align the disconnect valve connector with the pit module's blue telemetry connector and push the valve
connector into the pit module's connector.
4. Rotate the connector locking ring until the security holes align.
Caution Do not force the connector ends together. While you hold the disconnect valve's connector,
engage the pit module's connector by rotating the locking ring until both connectors are securely
connected. Twist only the connector locking ring, not the body of the connector. Twisting the connector
body could damage the pit module and disconnect valve's connector pins.
To attach an Itron Security Seal through the connector security hole
1. Insert the pointed end of the security seal through the inline connector and the pit module connector
security holes.
2. Insert the pointed end of the security seal into the capped end and push until the seal locks.
This completes the pit module and remote disconnect installation.