User's Manual

Installing the OpenWay Riva Water Pit Module
TDC
-1666-000 OpenWay Riva Water Pit Module Installation Guide 10
Proprietary and Confidential
Pit Modules with Integral Connectors
If pit modules with integral connectors (ERW-1601-00X) and the registers are not installed at the same time,
secure the protective environmental connector cover on the pit module using an Itron Security Seal (Itron part
number MSC-0018-001). Cable ties are not shipped with the pit module, but can be ordered from Itron. Use
the protective cover (on the pit module side) in the field for up to one year.
Warning If a three-port pit module is installed but the telemetry device is not
attached, the environmental cap (MSC-0019-008) must remain in place on the
blue connector (telemetry) to protect the connector from damage.
To install a Security Seal through the protective connector cover
1. Align the protective cover and connector security seal holes.
2. Insert the security seal pointed end through the security holes in the connector and protective cover.
3. Insert the pointed end of the security seal into the cap end and push until the seal locks.
Through Lid Installation
This section provides instructions to mount the pit module in a pit lid with a drilled, round 1-3/4-inch, 1-7/8-
inch, or 2-inch hole.
Through Lid Mount Required Tools and Hardware
This mounting method requires the Pit Lid Mounting Kit.
Pit Lid Mounting Kit (CFG-1601-001)
Note The Pit Lid Mounting Kit is not intended for applications involving vehicular traffic.