Initializing, Connecting, and Programming the OpenWay Riva Water Pit Module
TDC
-1666-000 OpenWay Riva Water Pit Module Installation Guide 7
Proprietary and Confidential
Connecting the Pit Module to a Remote Meter Register
Connect pit module cable to the register according to the following table.
Pit Module Connections
Register Manufacturer
Pit Module wire color
Red
(signal)
Black
(common)
White
(tamper)
Register screw color designator
Badger RTR (3-wire)
Red Black Green/bare
Badger RTR (2-wire)
Red Black No connection*
Badger M5000 Mag Meter
Out 1+ Out 2- Out 1+
Elster Digital
Black Green Red
Elster V100T
Black Red Blue
Itron (Actaris) Flostar (2-wire)
Cyble Sensor
Either wire
Remaining wire must be connected to both
pit module wires
Krohne IFC
Term B Term H Term B
RG3 Tomahawk
Green Black Green
Sensus PMM
Red Black Bare
Verifying Pit Module Operation
Use one of the following handheld computers to verify consumption:
• FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
• FC300 with SRead
Notes
• Each handheld radio requires special setup and configuration parameters to successfully read
and program the pit module. Refer to the respective meter reading application for specific
instructions.
• When comparing the actual register value to that reported by the pit module, please keep in
mind the ERT module's consumption value is updated once an hour when it is in Run Mode.
Caution Verifying the OpenWay Riva Water Pit Module operation requires an FC200SR or and
FC300 handheld computer running FDM v. 4.0 or higher. Legacy Itron handheld programming
devices cannot read the pit modules.