TDC
-1666-000 OpenWay Riva Water Pit Module Installation Guide 5
Proprietary and Confidential
This chapter provides the instructions to program and connect the pit module.
OpenWay Riva Water Pit Module Start-up
The pit module automatically:
• Detects the connected register type at the top of the hour, exits Factory Mode, and enters Run Mode.
• Detects an Itron Riva Leak Sensor.
OpenWay Riva Water Pit Module programming is required to:
• Change the operation mode
• Enter a utility ID or lock type.
• To enter an E-Coder 8-digit driver.
• Commission security
Itron strongly recommends performing a Check ERT with a handheld computer running FDM to verify the
pit module is operating correctly after installation. Performing a Check ERT will:
• Generate an immediate register read.
• Verify communication with the Riva Leak Sensor.
• Check for tamper flags.
Programming the Pit Module
Programming the pit module requires one of the following handheld computers running Field Deployment
Manager (FDM) version 4.0 or later.
• FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
• FC300 with SRead
For normal activation, connect the pit module to the water meter register and program the pit module using
FDM.
Connecting to a Meter Register Using the Inline Connector
The inline connector system provides easier general maintenance or system troubleshooting (see Using an
Inline Connector on page 23).
Connecting the OpenWay Riva Water Pit Module to a Remote
Meter Register
Order the 25-foot inline connector extension cable assembly (CFG-0151-401) to extend the cable of the pit
module.
C HAPTER 2
Initializing, Connecting, and Programming the OpenWay Ri
va
Water Pit Module