dlist Dlist will list the PETs that are active in the database along with associated packet
information.
elist Elist will list the PETs that are active in the database 3 column format, screen at a time.
gohop Gohop allows the operator to override the random number generator for the first large
block transmission frequency. The local transmitting Class 1 PETRC will initiate its
hopping sequence with the gohop value entered. The hopping sequence is tied to the
serial number, however, the starting hop is redirected.
gohop=24 for causing the first transmission to utilize frequency 926.1Mhz
lbint Lbint sets the repeat interval for sending pre-emptive large block transmissions.
lwbat Lwbat will reset all of the PETs low battery flag that reside in the PETRC’s database.
pchnl Pchnl sets the acquisition channel that the receiver will utilize when in acquisition mode.
pdump Pdump will display the PET tracking information on the screen and then return
the system immediately to automatic unattended operation.
plist Plist displays the operating parameters that deal with PET tracking and database
management.
Optional commands for shorter lists are: plist1, plist2 and plist3.
ptime Ptime sets the PET receive interval time, normally set to 600 seconds which equals 10
minutes.
rptcl Rptcl allows the operator to set the repeater class of operation.
rptcl=0 would establish the local PETRC as a base unit
rptcl=1 would establish the local PETRC as a repeater
rxtim Rxtim sets the amount of time that the PET will remain active in the database without
being updated by a more recent transmission.
rdiag Rdiag allows the operator to select the low level diagnostic mode of operation. This
mode is used for testing the PETRC on the test bench.
rxwin Rxwin sets the window size for tracking PET transmissions.
modem Modem allows the operator to edit the modem initialization string.
slist Slist Allows the operator to request information on a single PET in the local PETRC’s
database.
snchg Snchg is used to enter the local PETRC’s serial number into protected memory.
snchg=1202354 sets serial number 1202354 into protected memory