Installation Guide

1. Position the flood sensor on the pipe using the correct pipe cradle for the pipe's orientation.
Note: Place the sensor 6 to 12 inches above the ground or floor but below the OWRGD.
2. Place the open band clamp around the pipe and flood sensor.
3. Tighten the band clamp enough to ensure the sensor cannot rotate or slip on the pipe.
Mounting the Flood Sensor on a Flat Surface
1. Locate the installation area on a flat surface 6 to 12 inches above the ground or floor but
below the OWRGD.
Note: The three mounting holes on the flood sensor may be used as a drilling template
for installation.
2. Secure the flood sensor to a wall or other flat surface by tightening three user-supplied
14 August 2020 815-0382-00 23
OpenWay Riva Gas Disconnect Installation Guide 4 Installing the OWRGD