When the OWRGD is mounted in horizontal piping, mount the device with the top surface (the
area with the product label) away from walls and structures.
When the OWRGD is mounted on vertical piping, do not mount the device in a vertical down flow
position (with the flow arrow point down). The top surface (the area with the product label) may
point to the side but not toward nearby walls or structures. Following these installation best
practices will optimize communications and prevent debris from accumulating on the valve seal
surface. Do not mount the OWRGD in a position that places the antenna against a structure or in
foliage.
The OWRGD recommended mounting positions are as follows:
Install the OWRGD in an orientation that positions the antenna as far from walls, meters, or
piping as possible. Ensure the following parameters: