- OpenWay Riva Gas Remote Disconnect Installation Guide Overview
- About the OpenWay Riva Gas Remote Disconnect
- Installing the OpenWay Riva Gas Remote Disconnect
- Connecting the Flood Sensor to the OpenWay Riva Gas Remote Disconnect
- OpenWay Riva Gas Remote Disconnect Operations
OpenWay Riva Gas Remote Disconnect Valve Commands
FDM Tools Valve Commands provide the interface to complete and view the listed
OpenWay Riva Gas Remote Disconnect (OWR-GRD) Valve Commands.
• Valve Status
• Connect
• Disconnect
• Commission
• Decommission
1. Valve Status
Selecting Valve Commands > Valve Status returns the listed information.
• Endpoint ID
• Device Type. The device type for the OpenWay Riva Disconnect device is OWR-GRD.
• Valve State
• Service Control State
• Commissioned
• Active Events
• Last Operation Method
• Last Operation Detail
• Last Operation Time
• External Sensor
Emergency override
In an emergency situation, operation of the valve under conditions outside of normal
operating parameters or following a flood related auto-closure is possible by acknowledging
the warning pop-up in FDM. Itron assumes no liability for failure of the OpenWay Riva Gas
Remote Disconnect to perform the requested action when the emergency override option is
selected. The use of the emergency override option voids any remaining warranty on the
OpenWay Riva Gas Remote Disconnect.
Caution:
Forcing an emergency override could result in damage to the valve or
failure of the valve to operate.
FDM offers the option to perform an Override action (Close or Arm) if any of the listed
conditions are reported by the OpenWay Riva Gas Remote Disconnect.
• Previous auto-disconnect due to immersion of an attached flood sensor in water.
• The current valve temperature is outside of the specified operating parameters (for
example, less than -20° F or greater than 150° F).
• Valve actuation count exceeded 80.
OpenWay Riva Gas Remote Disconnect Operations
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 22