Installation Guide

Table Of Contents
Performing a Get Commands
1. Open FDM.
2. Click the tools icon on the upper left corner.
3. Select Endpoint Tools.
4. Click the computer icon in the upper left corner.
5. Select Get Commands.
6. Enter the OpenWay Riva Gas Remote Disconnect device ID.
7. From the Device Type drop-down list, select OWR-GRD.
8. Click the + icon.
The Device ID is added to the Device Type list.
Note: Several devices may be added to the Device Type list prior to communicating with
the server.
9. Click OK.
The programming device communicates with the server. The red X next to the Device ID
changes to a secure lock symbol.
Programming the OpenWay Riva Remote Disconnect
1. Select Program Endpoint.
2. Enter the OpenWay Riva Gas Remote Disconnect Endpoint ID.
3. Confirm or enter the Audit Mode Duration.
4. Browse to and select the OWOC file to upload.
5. Click Next.
Screens appear showing the programming parameters.
6. Click Finish.
The OpenWay Riva Gas Remote Disconnect is ready to commission.
Performing Network Operations
FDM Tools provides the interface to the perform the listed Network Operations.
Force Registration
Set BubbleUp Mode
Close Session
For more information about performing OpenWay Riva Network Operations, see the FDM
Mobile Application Guide, FDM Tools. For documentation information, see Related
documents on page 10.
OpenWay Riva Gas Remote Disconnect Operations
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 21
Proprietary and Confidential