Note: Place the sensor 6 to 12 inches above the ground or floor but below the OpenWay
Riva Gas Remote Disconnect.
2. Place the open band clamp around the pipe and flood sensor.
3. Tighten the band clamp enough to ensure the sensor cannot rotate or slip on the pipe.
Mounting the flood sensor on a flat surface
1. Locate the installation area on a flat surface 6 to 12" above the ground or floor but below
the OpenWay Riva Gas Remote Disconnect.
Note: The three mounting holes on the flood sensor may be used as a drilling template
for installation.
2. Secure the flood sensor to a wall or other flat surface by tightening three user-supplied
screws through the flood sensor's mounting flanges.
Installing the OpenWay Riva Gas Remote Disconnect
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 17