12. Install the CGR's IOS to 15.8(3)M3b via the FND, using the following commands. Navigate
to Config > Firmware Update, select the Firmware Update Group in which the CGR
resides, click the Install Image button.
Note: It may take one hour to complete, then FND should display UPGRADE_COMPLETE.
13. Check the new IPv6 prefix is updated in the CGR configuration using the CGR CLI show
ipv6 int L0. Under Global unicast address(es) verify that the listed IPv6 address and
subnet were derived from the new IPv6 base address that was entered into the CNR, or
Infoblox in Step3.
Note: You can also verify the IPv6 Prefix is updated in the FND CGR Device info >
Running Configuration tab.
14. Physically install the CAM3 into the slot in the CGR where the CAM1 was installed.
15. From a Putty session to the CGR, power on the CAM3 using the following commands:
config t
no hw-module poweroff 5
end
16. From a Putty session to the CGR, type the following command to verify that IOx is registered
with the CGR:
Show iox host list
EXAMPLE OUTPUT
ZTDGLO-FAR361#show iox host list
Host Name IPV4 Address IPV6 Address IOX Client Version
ZTDGLO-FAR361-GOS-1 10.8.178.58 fe80::4603:a7ff:fe45:90ac 0.4
------------------------------------------------------------------------
17. Upgrade the new ACTD via the FND, using the following ioxclient commands:
ioxclient.exe pr a FAR361
ioxclient.exe application list
ioxclient.exe application install actd <dir path>\app-actd-ver-4.5.8.tar
ioxclient.exe application list
ioxclient.exe application activate actd
ioxclient.exe application start actd
ioxclient.exe application list