b. In Infoblox DHCPserver, go to Data Management > IPAM and add the new IPv6 Network
to be used by the CAM3M once it is provisioned.
Note: If you are unfamiliar with this process, please contact your Itron representative for
assistance.
Note: The following steps affect your mesh service and should be executed just before
starting to replace the CAM1 and upgrading the CGR.
4. On the CGR hosting the CAM1, remove the current version of Adaptive Communications
Technology Daemon (ACTD) using the following commands:
show iox application actd
iox application uninstall actd
5. Delete the CAM1 from the FND before you add the CAM3M using the FND commands.
Navigate to Devices > Field Devices > Select CAM1 (check the box next to the CAM) >
More Action > Remove Devices.
6. Import the CAM3M into the FND using the FND commands. Navigate to Devices > Field
Devices > Add Devices. Browse to the directory where the Import file for the CAM3M is
located, select it and click Add.
7. Open a Putty session to the CGR and power on the CAM1 using the following commands:
config t
no hw-module poweroff 5
end
Note: Step 7, assumes the CAM1 is installed in slot 5 of the CGR.
8. Verify that the CAM1 has been powered down using the following commands:
show module
Note: The command output should show that module 5 is powered-dn
9. Physically remove the CAM1 from the CGR.
10. Edit the existing CGR FND Import Common Separated Values (CSV) file and update it with
the new IPv6 Prefix in the following fields: meshPrefixConfig, meshAddressConfig,
gosGwyV6Address (or ioxGwyV6Address). Then update the CGR properties in FND using
the following commands. Navigate to Devices > Field Devices > Bulk Operations >
Change Device Properties. Browse to the directory where the updated CGR Import file
for the CGR is located, select it and click Change.
11. Open Config Properties tab in Devices > Field Devices > CGR Device info page to
verify that Prefix Config, IP Address Config and IOx Node Gateway IPv6 Address is
changed reflecting the new IPv6 Prefix.