Figure 85Using the Bulkhead Connector Assembly Extension Cable
While replacing the CAM, the CGR may have automatically logged you out. The CGR
automatically logs out the user after 10 to 15 minutes of inactivity. Log back on to the CGR and
return to the (config) prompt as described earlier.
Important! The CAM3S/CAM3M only fits into Slot 5 of the CGR. In this example, the
existing CAM is located in Slot 4. If your existing CAM is located in Slot 5, the same
procedure applies.
5. At the config prompt, enter hw-module power off 4 (Slot 4), see item 1.
Note: If the CAM is located in Slot 5, enter hw-module poweroff 5.
6. At the config prompt, enter do show module, see item 2.
7. Verify that the new Status indicates powered-dn, see item 3.
02 March 2020 815-0080-00 Itron, Inc. Page 81 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 7 Replacing an Existing CAM with a New CAM3S/CAM3M in the Field