Figure 84Sliding the Existing CAM Out of the CGR
21. Once the CAM is removed, remove the new CAM3S/CAM3M from its antistatic bag, and
now place the CAM into the anti-static bag.
Installing the New CAM3S/CAM3M
1. Insert the new CAM3S/CAM3M into Slot 5. Lightly push down on the CAM3S/CAM3M's
handles. You may need to vertically rock it to fully seat.
Caution: Do not force the CAM3S/CAM3M into place.
2. Tighten the two Phillips screws securing the CAM3S/CAM3M into the CGR. Torque the
captive screws to approximately 10in-lb.
3. Insert the RF Cable onto the QMA Connector.
4. Insert the 2.5mm end of the Bulkhead Connector Assembly Extension Cable (P/N 590-
0420-00) into the 6-Pin Connector, see item 1, on the front of the CAM3S/CAM3M. Insert
the 4.20mm end, see item 2, into the PLCSignal Cable, see item 3. The Bulkhead
Connector Assembly Extension Cable (P/N 590-0420-00) converts the 6-Pin from a
4.20mm to 2.5mm size.
02 March 2020 815-0080-00 Itron, Inc. Page 80 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 7 Replacing an Existing CAM with a New CAM3S/CAM3M in the Field