Installation Guide

Table Of Contents
Figure 81PuTTY Screen - Power Down CAM
After you have powered down the existing CAM, verify its actual location.
Important! The CAM3S/CAM3M only fits into Slot 5 of the CGR. In this example, the
existing CAM is located in Slot 4. If your existing CAM is located in Slot 5, the same
procedure applies.
15. Locate the actual Slot used by the existing CAM as identified using the PuTTY application.
16. Visually verify the Slot is occupied by the existing CAM. The CAM features include: 2 RF
QMA Connectors, see item a, and 1 6-Pin PLC Connector that is 4.20mm size, see item b, 1
mini USB Connector, see item c. All located on the front.
Figure 82CAM Features
After visually verifying the existing CAM, it may be removed from the CGR.
02 March 2020 815-0080-00 Itron, Inc. Page 78 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 7 Replacing an Existing CAM with a New CAM3S/CAM3M in the Field