Figure 79PuTTY Configuration Screen
After the PuTTY application connects to the CGR, a console terminal appears. If you do not see
a console terminal prompt, press the Enter key until the console terminal prompt appears. If you
still do not get a prompt, exit the PuTTY application and switch the baud rate (Speed) to a new
baud rate other than 9600. Make sure that the cable is attached and undamaged.
Important! The CAM3S/CAM3M only fits into Slot 5 of the CGR. In this example, the
existing CAM is located in Slot 4. If your existing CAM is located in Slot 5, the same
procedure applies.
7. Type enable at the prompt, see item 1.
8. Type the console password and press the Enter key, see item 2.
Note: The password for every CGR is different. The password does not appear on the
screen.
9. Type show module, see item 3.
10. Confirm that the Itron CAM location is shown. For example, CGR 1000 Third Party Module,
Mod 4 is Slot 4. The Status of ok indicates the CAM is powered and active.
02 March 2020 815-0080-00 Itron, Inc. Page 76 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 7 Replacing an Existing CAM with a New CAM3S/CAM3M in the Field