Cable Color Function Wire#
Black Neutral 1
Black Line 1 2
Black Line 2 3
Black No connection and should be insulated. 4
Green/Yellow Ground 5
Table 67Split Phase Wiring (240VAC)
Caution: No other voltages or any form of three phase power should be connected.
A 3 Phase circuit does not meet FCC or ISED compliance requirements.
3. Connect the 5-Pin Male end connector of the ACT Coupler Unit, see item 2, to the CGR
Power to the center Bulkhead Connector, see item 1, (Power Output) on the bottom of the
ACT Coupler Unit.
Figure 68Power Output Connection Location
4. Connect the 3-Pin Female end of the ACT Coupler Unit, see item 2, to the CGR Power
Cable to the Bulkhead Connector, see item 1, (Power Input) on the bottom of the ACT
Coupler Unit.
02 March 2020 815-0080-00 Itron, Inc. Page 67 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 6 ACT Coupler Unit Installation (CAM3M Only)