Figure 63Mounting Bracket and Hex Bolt Installation
2. Insert the remaining three hex bolts, see item 2, on each side of the CGR into their
respective places.
Note: Insert all hex bolts on each side before securing tightly.
3. Tighten all hex bolts. Use a torque of 6 to 7ft-lb when tightening the bolts.
Figure 64Hex Bolts Location on Side of CGR
Installing the ACT Coupler Unit
1. Connect the 5-Pin Female External Power Supply Cable, see item 2, to the left-most
Bulkhead Connector, see item 1, (AC Power Input) on the bottom of the ACT Coupler Unit.
02 March 2020 815-0080-00 Itron, Inc. Page 65 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 6 ACT Coupler Unit Installation (CAM3M Only)