Installation Guide

Table Of Contents
6.
Figure 48System (SYS) LED Location
Installing the CAM3S/CAM3M Using the PLC Signal Cable
Caution: Do not connect PLC to a 3 Phase circuit, this configuration is not
approved and does not meet FCC and ISED compliance requirements.
1. Locate Slot 5 by the slot identifier label, see item 1, inside the CGR.
2. Loosen the two captive screws on the blank cover over Slot 5 and remove the cover. Use
either a #2 Phillips or a 9/32" flat blade screwdriver.
3. Insert the CAM3S/CAM3M in Slot 5 of the CGR. Ensure that the CAM3S/CAM3M PCBs
edge connector is on the right side and aligns with the Peripheral Component Interconnect
Express (PCI-E) 98-pin connector on the CGR mother board. Gently press the
CAM3S/CAM3M until the card-edge connector is firmly seated into the connector.
4. Tighten the retaining screws, see item 3, on the front of the CAM3S/CAM3M, securing the
module in place. Use either a #2 Phillips or a 9/32" flat blade screwdriver and apply a torque
of approximately 10in-lb.
02 March 2020 815-0080-00 Itron, Inc. Page 54 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 5 Radio Frequency and Power Line Carrier Installation