6.
Figure 13System (SYS) LED Location
Removing the CGR from the Pole
Before the remote antenna assembly can be attached to the CGR, for a CAM3S, you must first
disconnect the Power, the Ground Cable, physically unmount the CGR, and remove the CGR
mounting bracket so that you can access the connection points.
Warning! After removing the CGR from the pole, place the CGR on an electrostatic
discharge (ESD) protected mat to prevent personal injury and/or damage to the
electronic components.
1. Disconnect the power. See Disconnecting Power to the CGR.
2. Remove the 6AWG Ground Cable, see item 2, located on the bottom right side of the CGR
by removing the two screws from the ground lug, see item 1.
02 March 2020 815-0080-00 Itron, Inc. Page 27 of 102
OpenWay® Riva CAM3S and CAM3M Installation Guide 4 Star and Mesh Deployment Installation