User Manual
CGR ACT Coupler
Unit Installation
OpenWay® Riva™ CAM / ACT Coupler Unit 26
Install CGR Mounting Bracket
Illustration Callout Number Description
1
Alignment slots
2
4 - Hex head mounting bolts (8mm x 25mm)
supplied with the installation kit
3
Center stud with self-locking hex nut
1. Position the CGR mounting bracket over the center stud and slid down behind hex nut.
2. Insert the four 8mm x 25mm mounting screws supplied with the installation kit into the threaded holes in
the base mounting plate. Do not tighten bolts until all are started.
Note The four alignment slots in the mounting brackets allow the CGR and the coupler unit to be rotated
either clockwise or counter clockwise for alignment purposes. Inserting the mounting bolts as shown
allow the unit to rotate counter clockwise. Inserting all four bolts in the holes at the other end of the slot
allows the unit to be rotated clockwise.
3. Adjust the alignment of the CGR and coupler to the desired orientation and tighten the four mounting
bolts and the hex nut on the center stud. Use a torque of 6-7 foot-pounds when tightening the bolts and
nut.