User's Manual

SSI OPENWAY 2.0 SmartMeter User Guide
SMR45-4601B 14
5 SSI OPENWAY 2.0 Display Feature
Note: These display codes are only visible when the SmartSynch Option Board type is selected
in the meter program and the option board fields are enabled.
1. SmartSynch Identifier: In general, the meter program controls the number of displays, associated
fields, and display time. This 3-letter field identifies SmartSynch display among available displays.
Note: This is a user defined field and can be changed by the customer.
Values Description
SSI SmartSynch, Inc.
2. SmartMeter Warning: displays error codes generated by SmartSynch embedded software.
Normal operations – no errors
1
SmartMeter module’s NVRAM error
2
Read/write failure in the Common Configuration area - NVRAM
3
Read/write failure in the App. Specific Configuration area - NVRAM
4
Actual firmware binary image is corrupted
5
Firmware image decompression error
6
Meter clock deviation is greater than the maximum correction limit
7
Software watchdog triggered – processor is reset
Good. Warning. Error
3. Wireless Coverage Status: coverage status detected by the GPRS modem.
Values Description
1 In coverage: modem can hear the network
0 Out of coverage: modem can’t hear the network