Setup Guide
Table Of Contents
- Intelis Gas Meter Proving and Setup Guide
- Contents
- New in this Document
- 1 Important Safety and Compliance Information
- USA, FCC Part 15 Spectrum Compliance
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Australia, ACMA Spectrum Compliance
- Electromagnetic Compatibility
- Intrinsic Safety
- Lithium Battery
- Transportation Classification
- Electrostatic Discharge
- Electrostatic Ignition Hazard
- Device Cleaning
- Do Not Drop
- Product Standards
- 2 Overview
- 3 Proving
- 4 Proving the Intelis Gas Meter Using the Honeywell SNAP Proving System
- 5 Proving the Intelis Gas Meter Using the Measurement Systems Proving System
- 6 Proving the Intelis Gas Meter Using the Energy Economics (EEI) Proving System
- 7 Calibrating the Intelis Gas Meter
Note: All other settings (Tangents, Ultra Intest Lock, Ultra Adjust Lock and Station) on
the Test Options window are not relevant for the Intelis meter.
Proving the Intelis Gas Meter
1. Connect the EEI pulse prover cable (Itron part number CFG-7100-400) to the EEI prover
index eye connector.
2. Connect the Intelis Gas Meter end of the EEI pulse prover cable to the Intelis Gas Meter by
firmly pressing the aluminum round threads of the cable into the port. Begin by positioning
the cable at the 4:30 o'clock position. Tighten the cable to the 6:30 o'clock position.
Caution: Do not over tighten as doing so could damage the index housing or the
proving cable head.
Note: The Intelis Gas Meter automatically enters Test Mode when the pulse output cable
is connected to the meter.
08 July 2020 815-0154-00 REV 000 Itron, Inc. Page 57 of 66
Intelis Gas Meter Proving and Setup Guide
6 Proving the Intelis Gas Meter Using the Energy Economics (EEI)
Proving System