Note: Nozzle 192 CFH is typically used to exercise the Intelis Gas Meter.
4. Exercise the meter for 10 to 60 minutes until the Out Temp value does not vary by more than
0.2° F within a minute.
5. Close the nozzle.
6. Unclamp the meter.
7. Exit the Sensor Maintenance window by clicking Done in the lower right corner of the
window.
08 July 2020 815-0154-00 REV 000 Itron, Inc. Page 51 of 66
Intelis Gas Meter Proving and Setup Guide
6 Proving the Intelis Gas Meter Using the Energy Economics (EEI)
Proving System