Setup Guide
Table Of Contents
- Intelis Gas Meter Proving and Setup Guide
- Contents
- New in this Document
- 1 Important Safety and Compliance Information
- USA, FCC Part 15 Spectrum Compliance
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Australia, ACMA Spectrum Compliance
- Electromagnetic Compatibility
- Intrinsic Safety
- Lithium Battery
- Transportation Classification
- Electrostatic Discharge
- Electrostatic Ignition Hazard
- Device Cleaning
- Do Not Drop
- Product Standards
- 2 Overview
- 3 Proving
- 4 Proving the Intelis Gas Meter Using the Honeywell SNAP Proving System
- 5 Proving the Intelis Gas Meter Using the Measurement Systems Proving System
- 6 Proving the Intelis Gas Meter Using the Energy Economics (EEI) Proving System
- 7 Calibrating the Intelis Gas Meter
Specification Specification value
■
Valve: -13° F (-25° C) to +131° F (55° C)
■
RF: -40° F (-40° C) to +158° F (70° C)
■
LCD:-40F(-40C)to 185F(85C)
1
Storage temperature ratings -40° F (-40° C) to +158° F (70° C)
Battery information 4 Lithium manganese dioxide (LiMnO2) 'A' cell batteries, replaceable
Battery life 20 years for meter, RF, and valve using recommended operating parameters
Badging Standard aluminum manufacturing and optional customer badge
Test pulse weight (volume per
pulse)
0.10CF, 0.25CF, 0.50CF, 1.0CF, 10dm
3
, 50dm
3
Test pulse width 10 ms - 1000 ms (1 second)
Minimum compatible
collection software for Mobile
and Riva network
■
FCS v4.1
■
FDM Tools v4.2
■
ISM v3.6 (if using enhanced security)
■
Itron Mobile v1.5
■
Mobile Collection v3.8.2
Minimum compatible
collection software for Gen5
network
■
Gen3, 4, or 5 constantly powered device (CPD) hardware running UtilOS v5.0
■
FCSv4.3.1
■
FDM Tools v4.3
■
ISM 4.2
■
UtilityIQ v4.15
Standards Designed in compliance with ANSI B109.1, ANSIB109.0 (draft), and Measurement
Canada PS-G-06
Table 1Intelis Gas Meter specifications (continued)
1
Electro-optical characteristic and optical performance is affected during high temperature
operation (approximately 176°F/80°C to 185°F/85°C) and low temperature operation
(approximately -22°F/-30°C to -40°F/-40°C). Performance recovers under normal temperature
range.
Dimensions
This section lists the Intelis Gas Meter dimensions. Dimensions are listed in Imperial and Metric
units.
08 July 2020 815-0154-00 REV 000 Itron, Inc. Page 13 of 66
Intelis Gas Meter Proving and Setup Guide 2 Overview