Itron recommends these Intelis Gas Meter Test Mode parameter settings for the Measurement
Systems proving system:
■
Test Mode pulse weight: 0.25 CF
■
Test Mode pulse width: 150 ms
Temper the Meter by Exercising the Meter
1. Open the Measurement Systems Proving System application software.
2. Select Meter Setup to exercise the meter.
11 December 2019 TDC-1782-005 42
Intelis Gas Meter Installation Guide 5 Proving