Important: If Itron, Actaris, Sprague, or other is listed, it is still necessary to add a new
manufacturer name specifically for the Intelis Gas Meter. Itron suggests using ITRON-
RTY following the steps listed below. The MFR Type must have the RTY suffix to allow
setting and saving the revs desired for any given test and flow rate. Without the RTY
suffix, the settings will not be saved.
7. Select Meter_Table checkbox.
This step allows you to copy an existing meter setup and modify it to create the new
Intelis Gas Meter (for example, choose I-250, Itron). Select a similar meter's row
. Follow
the Meter-Table instructions: Click on the next open/empty row. To complete the addition,
click off of the table and select Add Chosen Meter. The following illustration shows the
successful copy of the I-250 meter to create the Intelis 250 MeterName, ITRON-RTY
MeterMfr.
8. Update the parameters in the table.
•
MeterName: Intelis 250
• MeterMfg: ITRON-RTY
• Open proof: 100
• Check proof: 100
• Other proof: 100
• Open flow: 250 (or the setting required by your utility)
• Check flow: 50 (or the setting required by your utility)
• Other flow: 100
• Open revs: 6
• Check revs: 2
Proving the Intelis Gas Meter
Intelis Gas Meter Installation Guide TDC-1782-002 27
Proprietary and Confidential