DRAFT
Appendix A - CCU4 Collector Specifications 39
POTS Cable
POTS Cable
Receiver
Table 12: POTS Cable Wire Specifications
Wire Color Signal Name
Green Tip
Red Ring
Black Ground
Yellow no connection
Table 13: Receiver Specifications
Specification Value
Control Interface Serial (TTL levels) 38400 bps
Command Interface Custom Itron API
Power Supply Requirements +5.5 VDC ± 5%, +3.6 VDC
Current Drain Sleep: < 5 mA
Receive: ?
Operating Frequency 910 MHz – 920 MHz
Sensitivity (50% packets) -112 dBm
Dynamic Range Without Attenuation: 55 dB
With Attenuation: 83 dB
Out-of-Band Rejection < 825 MHz: ? dB
< 890 MHz: ? dB
> 952 MHz: ? dB
> 1000 MHz: ? dB