Appendix A - CCU4 Collector Specifications 37
Communications Connector
Battery
Communications Connector
Input Current 1.0 A
RMS
Inrush
Power Conversion Efficiency ?
Surge & Transient Immunity ?
Table 8: Battery Specifications
Specification Value
Type Four-cell sealed lead acid battery pack
Power 8.8V, 2.5 Amp hours / 22 WHr
Life 4 hours after 5 years of typical use
Charge Time 16 hrs
Operating Temperature -20°C to +60°C (-4°F to +140°F)
Storage Temperature -40°C to + 60°C (-40°F to + 140°F)
Table 7: Power Specifications continued ...
Specification Value
Table 9: Communications Connector Specifications
Specification Value
Type 10 Base-T
Isolation > 2000V
Operating Temperature -40°C to +85°C (-40°F to + 185°F)
Surge / Lightning Immunity Per Bellcore GR-1089 Intra Building