User's Manual

Table Of Contents
TDC-0971-011 CCU 100 and Repeater 100 Installation Guide 19
This chapter provides the instructions to install a collector or repeater in the field, using
the Itron-recommended installation method.
The collector or repeater can be installed in a variety of ways. This chapter provides
several different collector or repeater installation profiles for both mains powered and
solar powered collectors or repeaters.
Warning Before installing a collector or repeater, ensure that the selected location
can support the weight of the collector or repeater and mounting hardware. A
thorough structural analysis should be performed by a registered professional
engineer at your desired location prior to installation. Itron is not responsible for
improper installations or for installations at a site that cannot adequately support the
collector or repeater.
Warning Do not install an 8.15 dBi antenna directly on the CCU/repeater. Antenna
installation directly on the CCU will compromise mechanical integrity and will not meet
the compliance requirement for a loss of 2.2 dB between the CCU/repeaters and the
8.15 dBi antenna.
Installation Overview
The following Itron-recommended collector or repeater installation profile describes the
procedure for mounting the collector or repeater to a 2-inch diameter vertical pipe. A
110V source supplies mains power to the collector or repeater.
There are several tasks in this installation profile. Each task is described in more detail in
the following sections.
Caution Prior to installing a collector in the field, be sure to configure it as described
in the the CCU 100 Collector Configuration Guide. A collector cannot be configured
after it has been installed in the field. Repeaters do not require pre-installation
configuration.
1. Attach the local GPS/WAN antennas (if necessary).
2. Attach the direct mount 900 MHz antenna on page 20 (if necessary).
3. Attach the CCU/repeater to the mounting surface.
4. Connect the cables on page 29.
5. Install the battery on page 34.
Caution Do not move or transport the collector without first disconnecting power.
Moving or tilting a collector with the power connected may cause the collector to
reset to the factory image.
6. Provide power on page 36.
7. Performing an antenna sweep test (on page 74).
C HAPTER 3