User's Manual
Table Of Contents
- Contents
- Before You Begin
- CCU/Repeater Basics
- Planning a CCU/Repeater Installation
- Installing the CCU/Repeater
- Battery Care and Replacement
- Detailed CCU/Repeater Specifications
- Status and Diagnostics
- Index
Attaching the CCU/Repeater
CCU 100 and Repeater 100 Installation Guide 27
Proprietary and Confidential
Davit Arm Mount
The figure below illustrates a typical utility pole or street light pole installation. The
CCU/Repeater is mounted on a davit arm or the street light arm. Two types of power
connections are typical. A photocell adapter cable may be used when the CCU/Repeater is
mounted on a street light arm. This cable plugs into the photocell sensor of the street light.
Use of the photocell adapter requires that the CCU/Repeater be grounded using the
grounding lug on the bottom of the CCU/Repeater. If the CCU/Repeater is mounted on a
davit arm with no street light, the power cable must be connected according to local
electrical codes.
To mount the CCU/Repeater on a davit arm
1. Using the two mounting brackets and four bolts, attach the mounting plate to the davit
arm.
2. Attach the mounting disc to the back of the CCU with the included parts in the
following order.
CCU > mounting disk > flat washer > lock washer > bolt