User's Manual

Table Of Contents
Performing an Antenna Sweep Test
CCU 100 and Repeater 100 Installation Guide 55
Proprietary and Confidential
CCU/Repeater status
Power source (AC or battery)
Battery state
Internal temperature
GPS status (number of satellites + GPS time and lat/lon position)
Firmware versions
Hardware versions
Event logs
Power outage logs
• WiFi access logs
High temp/Low temp alarms
Configuration collection
TX power
• Endpoint filtering settings
Configuration items settings
Firmware update interface
Force reboot
Performing an Antenna Sweep Test
If the endpoint antenna is remotely mounted for your installation, an antenna sweep test
must be performed to verify that the antenna functions within acceptable tolerances at your
installation site.
This test should be performed under the following conditions:
Beginning Frequency: 902
Ending Frequency: 928
VSWR Expected Results: Must be 1.5 or less for the specified frequency band.
Return Loss: Must be 18dB or better for the specified frequency band. Any
deviations from this return loss warrant further investigation.
Test Point: Feed line connected to the antenna at the top; test from the lightning (or
surge) arrestor to the antenna port.
Results: Test results must be saved in. PDF format.
Test Gear: Current and proper calibration; be sure that calibration is turned on during
the test. A qualified operator of the test equipment must perform the test.
Note If the system does not perform to the above test specifications, the reasons for
system failure and possible remedies must be identified before leaving the
installation site.