Installation Guide
Table Of Contents
- CCU 100 and Repeater 100 Installation Guide
- Important Safety and Compliance Information
- 1 Before You Begin
- 2 CCU/Repeater Basics
- 3 Planning a CCU/Repeater Installation
- 4 Installing the Collector or Repeater
- 5 Battery Care and Maintenance
- A Detailed Collector or Repeater Specifications
- B Port and Protocol Requirements
- C Status and Diagnostics
- D Changing the Repeater Password
- E Antenna Line Sweeps Procedure
- Anritsu Site Master Calibration
- Testing on a Network Device with a Remotely-Mounted 915 MHz Antenna
- Understanding Party Responsibilities
- Itron ChoiceConnect Antenna and Line Sweep Test Form
- Itron ChoiceConnect 915 MHz Antenna Specifications
- Typical Coaxial Cable Specification Summary Table
- Sample Sweeps Output
- F Grounding Specifications
- Understanding Grounding and Bonding
- Exterior Grounding System Design for Concentrators
- Equipment Buried Ground Ring
- Chemical Ground Rod Installation
- Itron Concentrator Equipment
- Installing Coax Ground Kits
- Collector Sites with Indoor Itron TCU / CCU Equipment
- Grounding Rooftop Network Devices
- Down Conductor Installation
- Cold Water Pipe Option
- Building Steel Option
- Antenna and Coax Grounding - Rooftops
- Grounding antennas on rooftops
- Cable Tray Grounding
- Water Tower Grounding
- New Wooden and Concrete Antenna Poles
- Equipment Shelter Grounding
- Repeaters on Communication Tower Sites
- Repeaters on Rooftops
- Multiple Story Site Ground System
- Down Conductors Installation - Building / Shelter Penetrations
- Down Conductors Installation - Limits of Bend Radius
- Down Conductors Installation Connection Methods
- Cable Entrance Facilities
- Clamp-On Ground Resistance Testing
- Understanding Party Responsibilities
Fixed Network database/NPA server outbound traffic
Source
address
Source
port
Destination
address
Destination
port
Protocol Required for
operation
Purpose
Fixed Network
database
server
Any Collectors
(any)
4443** HTTPS Yes Collector
commands and
diagnostic portal.
Fixed Network
database
server
Any Collectors
(any)
22 SSH Optional Itron collector
diagnostics
(CCU100 only).
Fixed Network
NPA server
Any 198.182.8.60 21 FTPS Optional Itron engineering
external NPA
server.
Fixed Network
database
server
Any ftp2.itron.com 21 FTP Recommend
ed
Itron Support
Services.
Fixed Network database/NPA server outbound traffic
Source
address
Source
port
Destination
address
Destination
port
Protocol Required
for
operation
Purpose
Fixed
Network
database
server
Any Collectors (any) 4443** HTTPS Yes Collector
commands and
diagnostic portal.
Fixed
Network
database
server
Any initial
configuration
router DHCP IP
addresses
4443** HTTPS Yes Collector shutdown,
reboot, etc.
Collector
commands and
diagnostic portal
router required
for v4.2 collectors
only.
Fixed
Network
database
server
Any spatial.virtualear
th.net
443 HTTPS Yes Geocoding web
service for device
maintenance.
Fixed
Network
database
server
Any www.mlogonlin
e.com
80 HTTP Yes Leak sensor data
export to
mlogonline.
Fixed
Network
workstation
Any dev.virtualearth.
net
80 HTTP Yes Virtual Earth
access for Network
23 June 2020 TDC-0971-012 Itron, Inc. Page 82 of 134