Installation Guide

Table Of Contents
Warning! There is a risk of explosion if the battery is replaced by an incorrect type.
Always replace with Itron part number BAT-0045-005.
For information on battery disposal or recycling, contact EnerSys at 1.800.363.7797 or
recycling@enersys.com.
Replacing the Battery
1. Remove the battery compartment cover by loosening the four screws securing it.
2. Slide the battery out of the battery compartment.
3. Carefully, disconnect the four pin connector.
4. Connect the new battery's four pin connector and route the cable and ferrite bead
appropriately.
5. Slide the new battery into the battery compartment.
6. Replace the battery compartment cover, and torque the screws to 6 inch-pounds.
23 June 2020 TDC-0971-012 Itron, Inc. Page 73 of 134
CCU 100 and Repeater 100 Installation Guide 5 Battery Care and Maintenance