Installation Guide

Table Of Contents
4
Installing the Collector or Repeater
This chapter provides the instructions to install a collector or repeater in the field, using the Itron-
recommended installation method.
The collector or repeater can be installed in a variety of ways. This chapter provides several
different collector or repeater installation profiles for both mains powered and solar powered
collectors or repeaters.
Warning! Before installing a collector or repeater, ensure that the selected location can support the
weight of the collector or repeater and mounting hardware. A thorough structural analysis should be
performed by a registered professional engineer at your desired location prior to installation. Itron is
not responsible for improper installations or for installations at a site that cannot adequately support
the collector or repeater.
Do not install an 8.15 dBi antenna directly on the CCU or Repeater. Antenna installation directly on
the CCU will compromise mechanical integrity and will not meet the compliance requirement for a
loss of 2.2 dB between the CCU or Repeater and the 8.15 dBi antenna.
Installation Overview
The following Itron-recommended collector or repeater installation profile describes the
procedure for mounting the collector or repeater to a 2-inch diameter vertical pipe. A 110V
source supplies mains power to the collector or repeater.
There are several tasks in this installation profile. Each task is described in more detail in the
following sections.
Caution: Prior to installing a collector in the field, be sure to configure it as described
in the the CCU 100 Collector Configuration Guide. A collector cannot be configured
after it has been installed in the field. Repeaters do not require pre-installation
configuration.
1. Attach the external GPS/WAN antennas (if necessary).
2. Direct Mount Standard (5.15 dBi or 5.5 dBi) 915 MHz Antenna on page 33 (if
necessary).
3. Attach the CCU/repeater to the mounting surface.
4. Cables on page 44.
5. Battery on page 49.
23 June 2020 TDC-0971-012 Itron, Inc. Page 32 of 134